PASS INTERNATIONAL CODE COUNCIL FIRE-INSPECTOR-II EXAM AND GET CERTIFIED WITH EASE

Pass International Code Council Fire-Inspector-II Exam and Get Certified with Ease

Pass International Code Council Fire-Inspector-II Exam and Get Certified with Ease

Blog Article

Tags: Most Fire-Inspector-II Reliable Questions, New Fire-Inspector-II Test Book, Fire-Inspector-II Valid Exam Labs, Vce Fire-Inspector-II File, Exam Fire-Inspector-II Simulator Free

In order to ensure the quality of our Fire-Inspector-II actual exam, we have made a lot of efforts. Our company spent a great deal of money on hiring hundreds of experts and they formed a team to write the work. The qualifications of these experts are very high. They have rich knowledge and rich experience on the Fire-Inspector-II Study Guide. So they know every detail about the Fire-Inspector-II exam questions and can make it better. With our Fire-Inspector-II learning guide, you will be bound to pass the exam.

We know that you care about your Fire-Inspector-II actual test. Do you want to take a chance of passing your Fire-Inspector-II actual test? Now, take the Fire-Inspector-II practice test to assess your skills and focus on your studying. Firstly, download our Fire-Inspector-II free pdf for a try now. With the try, you can get a sneak preview of what to expect in the Fire-Inspector-II Actual Test. That Fire-Inspector-II test engine simulates a real, timed testing situation will help you prepare well for the real test.

>> Most Fire-Inspector-II Reliable Questions <<

New Fire-Inspector-II Test Book | Fire-Inspector-II Valid Exam Labs

Our 67 - Fire Inspector II Exam (Fire-Inspector-II) exam dumps comes in three formats: International Code Council Fire-Inspector-II PDF dumps file, desktop-based practice test software, and a web-based practice exam. These versions are specially designed to make 67 - Fire Inspector II Exam (Fire-Inspector-II) preparation for users easier. Fire-Inspector-II Questions in these formats of Dumpexams's material are enough grasp every test topic in the shortest time possible.

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q53-Q58):

NEW QUESTION # 53
Given: A nonsprinklered commercial Type II-B building has a fire flow requirement of 7,000 gpm. If a sprinkler system is installed throughout the building, the new required fire flow is at least ___ gpm. (Assume that the new required fire flow is sufficient to meet the requirements of the sprinkler system.)

  • A. 2,250
  • B. 2,000
  • C. 1,500
  • D. 1,750

Answer: C

Explanation:
IFC Section 903.3.5 and Appendix B (Fire-Flow Requirements) allow a reduction in fire flow when sprinklers are installed. For a Type II-B building (noncombustible, unprotected), the base fire flow (7,000 gpm) reflects a large, unsprinklered structure (e.g., per Table B105.1(2)). With full sprinkler protection, IFC B105.2 permits a reduction to as low as 25% of the original flow or the sprinkler demand (whichever is greater), typically
1,500 gpm for commercial buildings per NFPA 13 standards, assuming adequate water supply. Options B, C, and D exceed this minimum without justification. Thus, A is correct.


NEW QUESTION # 54
In a control area where flammable liquid storage containers are in piles, there shall be a minimum of __ in. of clearance between the top of the storage and the deflector or discharge orifices of a sprinkler system.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
Clearance Requirement for Sprinkler Systems Over Flammable Liquid Storage According to International Fire Code (IFC) 2021, Section 5004.6 and NFPA 30: Flammable and Combustible Liquids Code, Section 16.5.1, there must be a minimum of 18 inches of clearance between the top of flammable liquid storage and the deflector or discharge orifices of a sprinkler system.
This ensures unobstructed sprinkler discharge for effective fire suppression.
2. Why 18 Inches is the Correct Answer
The 18-inch clearance allows sprinklers to operate properly, ensuring water distribution is not blocked by stored materials.
NFPA 13 also mandates an 18-inch minimum clearance for standard storage applications with sprinklers.
3. Verification of Other Options
Option B (24 inches) - Incorrect, as the IFC and NFPA specify 18 inches as the minimum requirement.
Option C (30 inches) - Incorrect, as this exceeds the required minimum clearance.
Option D (36 inches) - Incorrect, as the IFC and NFPA do not require this much clearance.
Reference Sources:
International Fire Code (IFC) 2021 - Section 5004.6 (Sprinkler Clearance Over Flammable Liquid Storage) NFPA 30: Flammable and Combustible Liquids Code - Section 16.5.1 NFPA 13: Standard for the Installation of Sprinkler Systems - Minimum Clearance Requirements ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: A. 18 inches. #


NEW QUESTION # 55
The maximum time which a hazardous materials storage tank may be left unused, before safeguards as required by the code official are necessary, is ___ days.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
According to fire codes, a hazardous materials storage tank that remains unused for more than 90 days requires additional safeguards as determined by the code official. This is to prevent leaks, contamination, and fire hazards due to deterioration or potential unauthorized access.
Reference to Fire Inspector Documentation:
1. 2021 International Fire Code (IFC) - Section 5704.2.13.1.3 (Out-of-Service Storage Tanks) IFC 5704.2.13.1.3 states that a hazardous materials storage tank left unused for more than 90 days must be safeguarded by the measures required by the code official. These measures may include:
Removal of hazardous substances
Proper tank inerting or sealing
Leak prevention and periodic inspections
2. NFPA 30 - Flammable and Combustible Liquids Code (2021 Edition)
NFPA 30, Section 21.7.1 aligns with IFC guidelines, stating that inactive hazardous materials tanks must be properly maintained or decommissioned after 90 days.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 30 days is too short; the IFC specifies 90 days as the threshold for requiring safeguards.
Option B (Incorrect): 60 days is also too short based on the IFC and NFPA 30 requirements.
Option C (Correct): 90 days is the correct limit before safety measures are required.
Option D (Incorrect): 120 days would exceed the safety limit, leading to potential hazards.
Thus, the correct and verified answer is: C. 90 days.


NEW QUESTION # 56
A code official may allow the occupant load of a building or room to exceed that specified in the building code if additional exit facilities are provided, all other egress requirements are met, and the maximum occupancy does not exceed one occupant per sq. ft. of occupiable floor area.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
A code official may allow the occupant load to exceed the building code requirements if additional exit facilities are provided, all egress requirements are met, and the maximum occupancy does not exceed one occupant per 10 sq. ft. of occupiable floor area.
Reference to Fire Inspector Documentation:
1. 2021 International Building Code (IBC) - Table 1004.5 (Occupant Load Factor) The minimum safe occupancy load factor is 10 sq. ft. per occupant, meaning no space can have more than 1 person per 10 sq. ft.
Fire code officials can approve increased occupancy only if extra exits are provided, ensuring compliance with egress and fire safety rules.
2. 2021 International Fire Code (IFC) - Section 1004.2 (Increased Occupant Load Allowance) Allows for an increased occupant load only if additional exits and egress requirements are met but never beyond 1 person per 10 sq. ft.
Detailed Explanation of Answer Choices:
Option A (Incorrect): 1 occupant per 3 sq. ft. is too high and would violate egress safety regulations.
Option B (Incorrect): 1 occupant per 5 sq. ft. still exceeds safety limits.
Option C (Incorrect): 1 occupant per 7 sq. ft. is not the minimum required standard.
Option D (Correct): 1 occupant per 10 sq. ft. is the minimum limit for allowing an increased occupant load under IFC 1004.2 and IBC Table 1004.5.
Thus, the correct and verified answer is: D. 10.


NEW QUESTION # 57
Quantities of flammable liquid storage in a control area of an S Occupancy may be doubled when:

  • A. the control area exceeds 50,000 sq. ft.
  • B. permission is granted by the chief.
  • C. the control area is provided with exhaust ventilation in accordance with fire code requirements.
  • D. the building is protected with automatic sprinklers.

Answer: D

Explanation:
The storage of flammable liquids in control areas within an S Occupancy (Storage Occupancy) is governed by the 2021 International Fire Code (IFC), Section 5003 - Hazardous Materials, and Table 5003.1.1(1).
IFC Section 5003.1.1(1) - Maximum Allowable Quantity (MAQ) Adjustments:
The maximum allowable quantity (MAQ) of flammable liquids in a control area may be doubled if an approved automatic sprinkler system is installed throughout the building.
Why Other Options Are Incorrect?
A: Permission is granted by the chief.
Fire officials can enforce code requirements but do not have the authority to override MAQ limits unless explicitly allowed in the code.
B: The control area exceeds 50,000 sq. ft.
The code does not specify an increase based solely on size; the sprinkler system is the determining factor.
D: The control area is provided with exhaust ventilation in accordance with fire code requirements.
While ventilation is important for hazardous material safety, it does not allow for an increase in the maximum storage quantity.


NEW QUESTION # 58
......

The passing rate is the best test for quality of our Fire-Inspector-II study materials. And we can be very proud to tell you that the passing rate of our Fire-Inspector-II Exam Questions is almost 100%. That is to say, as long as you choose our study materials and carefully review according to its content, passing the Fire-Inspector-II Exam is a piece of cake. We're definitely not exaggerating. If you don't believe, you can give it a try.

New Fire-Inspector-II Test Book: https://www.dumpexams.com/Fire-Inspector-II-real-answers.html

We make the commitment that if you fail to pass your exam by using Fire-Inspector-II study materials of us, we will give you refund, Don’t lose heart, International Code Council Most Fire-Inspector-II Reliable Questions We are the most authority and innovation that keep head of fierce competitors, International Code Council Most Fire-Inspector-II Reliable Questions I hope our study materials can accompany you to pursue your dreams, The braindumps of the testing engine is a simulation of the Fire-Inspector-II braindumps actual test that you can feel the atmosphere of the International Code Council real exam, and the answer is not shown in the process of Fire-Inspector-II braindumps test.

Root Causes Based on the Default Router's Fire-Inspector-II Configuration, How can I subscribe to a Pearson IT Certification newsletter, Wemake the commitment that if you fail to pass your exam by using Fire-Inspector-II Study Materials of us, we will give you refund.

Providing You Fantastic Most Fire-Inspector-II Reliable Questions with 100% Passing Guarantee

Don’t lose heart, We are the most authority and innovation Fire-Inspector-II Valid Exam Labs that keep head of fierce competitors, I hope our study materials can accompany you to pursue your dreams.

The braindumps of the testing engine is a simulation of the Fire-Inspector-II braindumps actual test that you can feel the atmosphere of the International Code Council real exam, and the answer is not shown in the process of Fire-Inspector-II braindumps test.

Report this page